Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
The Journal of Korean Academy of Prosthodontics ; : 354-361, 2011.
Article in Korean | WPRIM | ID: wpr-116127

ABSTRACT

There are still many limitations on fabricating dentures using digital method while computerized production of fixed prostheses utilizing intraoral scanner and CAD/CAM technology has propagated rapidly. Recently the digital solution of fabricating removable partial denture by applying haptic input device, electronic surveying, and rapid prototyping was introduced. In this case presentation, five patients were treated with surveyed crown and removable partial dentures by this digital solution. Fit of dentures was excellent except for one case which showed morphological difference between the actual teeth and that of master cast by the erroneous impression process. There also was not any problem of stability and retention after adaptation in the clinical setting.


Subject(s)
Humans , Crowns , Denture, Partial, Removable , Dentures , Electronics , Electrons , Prostheses and Implants , Retention, Psychology , Tooth
2.
Journal of Korean Society of Medical Informatics ; : 93-103, 2001.
Article in Korean | WPRIM | ID: wpr-187114

ABSTRACT

This study is intended to the diagnostic accuracy and reproducibility rate according to the input devices and the video signals, potential technical problems of the telepathology system and possible physical and psychological impacts. Web based in telepathology system had been developed and in use, but their functional capability and diagnostic accuracy are considered to be inferior to those of conventional optical microscope. We devised a telepathology system using our existing microscope equipped with CCD camera unit that has no restriction of network speed. Total 55 histopathologic cases from various organs were selected. Three pathologists are involved in making diagnoses. The resulting diagnostic accuracies were 1CCD camera with composite video signal was 86.2%, 3CCD camera with composite video signal was 93.1% and 3CCD camera with component video signal was 95.0%. The 3CCD camera with component video signal resulted 95.0% diagnostic accuracy and was superior to 1CCD and 3CCD camera with composite video signal. At this time of problems were not noted in the monitor quality.


Subject(s)
Diagnosis , Telepathology
3.
Korean Journal of Pathology ; : 1191-1198, 1999.
Article in Korean | WPRIM | ID: wpr-33755

ABSTRACT

Varieties of telepathology system had been developed and in use, but their functional capability and diagnostic accuracy are considered to be inferior to those of conventional optical microscope. This study is intended to find out: 1) the diagnostic accuracy and reproducibility rate according to the input devices and the video signals; 2) any potential technical problems of the telepathology system; 3) any possible physical and psychological impacts. We devised a virtual telepathology system using our existing microscope equipped with CCD camera unit that has no restriction of network speed. Total fifty-five surgical pathology cases from 11 different organs were selected. Three pathologists were involved in making diagnoses. The resulting diagnostic accuracies were: 1 CCD camera with composite video signal was 86.2%; 3 CCD camera with composite video signal was 93.1%; 3 CCD camera with component video signal was 95.0%. The 3 CCD camera with component video signal resulted in 95.0% diagnostic accuracy and was superior to 1 CCD camera with composite video signal. Some technical problems noted during this study were: the visual field of the virtual telepathology system was smaller by 43% than that of microscope; the difference of cell sizes between microscope and monitor; low resolution of image. Some physical and psychological symptoms were noted.


Subject(s)
Cell Size , Diagnosis , Pathology, Surgical , Telepathology , Visual Fields
SELECTION OF CITATIONS
SEARCH DETAIL